Rotary Evaporator Manufacturer: RE Series From 1L to 50L

UnionClay is a rotary evaporator manufacturer producing the RE series from 1L bench glassware to 50L pilot builds, in manual-lift and automatic-lift configurations. Parameter sheets cover RE-101, RE-201D, RE-301 and the RE-2000A/B/E group, and the factory matches each evaporator with the vacuum pump, chiller and bath it needs.

RE Series Coverage From Bench to Pilot

Six builds make up the current line, and they overlap on purpose: capacity bands repeat across lift types so a buyer chooses mechanics and budget tier separately from flask volume. Every product page below carries the same parameter-sheet data this page is built from.

BuildCapacity spanLift typeProduct page
Compact bench unit1L–3LStandardRotary Evaporator 1L-3L
Mid bench unit5LStandardRotary Evaporator 5L
Automatic bench unit1L–2LAutomaticAutomatic Lift Rotary Evaporator 1L-2L
Manual pilot unit10L–50LManualManual Lift Rotary Evaporator 10L-50L
Automatic pilot unit10L–50LAutomaticAutomatic Lift Rotary Evaporator 10L-50L
Configured workstationBy applicationBy configurationRotary Evaporator System

Parameter-Sheet Glassware Data for the RE Line

Glassware compatibility is where rotary evaporator orders go wrong most often, so here is the joint data exactly as the client parameter sheets list it. The detail worth noticing: RE-301 steps up to a 50# flange port on the rotary flask while the receiving side stays on the 35# spherical ground joint across the whole group — receiving glassware carries over between models, rotary flasks do not always.

SpecificationRE-101RE-201DRE-301RE-2000A / B / E
Rotary flask capacity1L1L3L1L
Rotary flask joint24# ground joint24# ground joint50# flange port24# ground joint
Receiving flask capacity1L1L1L1L
Receiving flask joint35# spherical ground joint35# spherical ground joint35# spherical ground joint35# spherical ground joint
Condenser (dia. x length)85 x 270 mm85 x 270 mm85 x 270 mmVertical condenser, 85 x 270 mm

Larger 10L–50L builds use scaled glassware confirmed per order; the bench-unit sheet above is the reference point for joint standards across the line.

Manual Lift or Automatic Lift — Picking the Right Build

Both lift types raise and lower the evaporating flask in and out of the bath; what you are paying for is how. Our honest take: at 1L–2L the automatic lift is a comfort feature, but at 10L–50L it becomes a handling decision — a loaded pilot-scale flask assembly is heavy, and motorized lift removes the most awkward manual step in the workflow.

Decision factorManual liftAutomatic lift
Available builds10L–50L pilot units1L–2L bench and 10L–50L pilot units
Flask handlingOperator raises and lowers assemblyMotorized raise and lower
Best fitBudget-led pilot installations with trained operatorsFrequent batch changes, heavy flasks, single-operator labs
Reference pagesManual 10L-50LAutomatic 10L-50L

A Complete Evaporation Station From One Factory

A rotary evaporator without vacuum and cooling is a rotating flask. The system-level build sheet defines what a working station includes, and because UnionClay also manufactures the support equipment, the matching happens inside one factory instead of across three suppliers.

System areaWhat the build sheet specifies
Process scopeRotary evaporation, vacuum concentration and solvent recovery
Heating optionsWater bath or oil bath by temperature requirement
ControlDigital temperature and rotation control options
Support equipmentVacuum pump, chiller and condenser matching
Selection dataBottle volume, solvent, bath temperature, vacuum and recovery rate expectations

The two pairings we configure most: a vacuum pump sized to the flask volume and solvent, and a recirculating chiller holding the condenser cold enough to keep recovery rates honest. The DLSB chiller line on this site is built in the same plant and shares the inquiry process.

Solvent Recovery Jobs the RE Line Runs

  • Solvent Recovery

    Pulling process solvent back out of a mixture under vacuum — the core duty the line is specified around, from 1L research batches to 50L pilot recovery.

  • Sample Concentration

    Concentrating extracts and reaction products gently at reduced pressure, where bath temperature and vacuum level matter more than raw speed.

  • Evaporation Under Vacuum

    Routine distillation-style evaporation work where the condenser and cooling source decide throughput.

  • Pre-Distillation Preparation

    Reducing volume ahead of fine separation on distillation equipment downstream.

The Pre-Quotation Review Our Engineers Run

Before any RE-series quotation goes out, the factory walks one checklist drawn from the selection basis on the product sheets. Six points, no exceptions: flask volume, condenser type, vacuum pump, cooling source, bath temperature, and lift mode — all read against your solvent’s characteristics. If a buyer cannot answer one of the six yet, we flag it rather than quote around it; an evaporator matched to the wrong solvent profile wastes everyone’s quarter. Factory background and inspection practice are documented on the quality and factory page.

Buyer FAQ for the RE Series

Which rotary evaporator capacity should I start with?

Match the rotary flask to your largest routine batch, not your largest imaginable one. The 1L–3L and 5L bench builds cover research work; move to the 10L–50L pilot units only when batch volume genuinely demands it, because glassware, bath and support equipment all scale with the flask.

What is the practical difference between manual and automatic lift?

Mechanically, only how the flask assembly is raised from the bath. Practically, automatic lift earns its place on 10L–50L builds where the loaded assembly is heavy and batch changes are frequent; on 1L–2L units it is a convenience choice.

Do I need a vacuum pump and chiller with the evaporator?

For solvent recovery, yes — the build sheet lists vacuum pump, chiller and condenser matching as standard system scope. UnionClay supplies both from the same factory so capacities are matched before shipment rather than discovered on site.

What flask joints does the RE series use?

Per the parameter sheets: 24# ground joints on the rotary flask for RE-101, RE-201D and the RE-2000 group, a 50# flange port on RE-301, and a 35# spherical ground joint on the receiving flask across all listed models.

What should I confirm before requesting a quotation?

The six review points: flask volume, condenser type, vacuum pump, cooling source, bath temperature and lift mode, plus the solvent you run. Send those and the factory can answer with a specific configuration instead of a range. General purchasing terms are on the FAQ page.

Tell Us Your Solvent, Flask Volume and Cooling Source

That one sentence is enough to start. Send it through the contact form or by email, and the reply will name a build from the table above — with the matching pump and chiller if you want the full station from one supplier.

Glassware and system data on this page are parsed from the RE-series parameter sheets published on the UnionClay rotary evaporator product pages. Configurations are confirmed per order before quotation.

Contact Us